• Features
  • Specifications

iM-100 Series

    Reliable Large Volume Memory

    Internal memory has 50,000 points to record.
    USB memory can be used up to 32GB.

iM-100 Series

Specifications
Model iM-101 iM-102 iM-103 iM-105
Telescope
Magnification / Resolving power 30x / 2.5"
Others: Length : 171mm (6.7in.), Objective aperture : 45mm (1.8in.) (48mm (1.9in.) for EDM), Image: Erect, Field of view: 1°30' (26m/1,000m), Minimum focus: 1.3m (4.3ft.) Reticle illumination: 5 brightness levels,
Angle measurement
Minimum Display 0.5"/1" (0.0001 / 0.0002gon, 0.002 / 0.005mil) 1"/5" (0.0002 / 0.001gon, 0.005 / 0.02mil)
Accuracy (ISO 17123-3:2001) 1" 2" 3" 5"
Dual-axis compensator Dual-axis liquid tilt sensor, working range: ±6'
Collimation compensation On/Off (selectable)
Distance measurement
Laser output*1 Reflectorless mode: Class 3R / Prism/sheet mode: Class 1
Minimum display Fine / Rapid : 0.0001m (0.001ft. / 1/16 in.) / 0.001m (0.005ft. / 1/8 in.) (selectable) Tracking / Road : 0.001m (0.005ft. / 1/8 in.) / 0.01m (0.02ft. / 1/2 in.) (selectable) 0.001 ft. / 0.01 ft., 1/16 in. / 1/8 in.)
General
Guide light*12 Green LED (524nm) and Red LED (626nm), Operating range: 1.3 to 150m (4.3 to 490ft.)
Laser-pointer*12 Coaxial red laser using EDM beam
levels 6’ (Inner Circle)
Dust and water protection / Operating temperature IP66 (IEC 60529:2001) / -20 to +60ºC (-4 to +140ºF)
Size with handle 183(W)x 181(D)x 348(H)mm
Instrument height 192.5mm from tribrach mounting surface
Weight with battery & tribrach Approx. 5.3kg (11.7lb)
Power supply
Battery Li-ion rechargeable battery BDC70
Application Program
On Board REM Measurement • 3D Coordinate Measurement • Resection • Stake Out • Topography Observation • Offset Measurement • Missing Line Measurement • Intersection • Surface Area Calculation • Route Surveying • Point to Line